MODEL
SPECIFICATIONS
NEXT STEPS
3133A1 |
10 mV/g sensitivity, 500g range, 3–foot integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–67 to +320°F Operation
1.02 mV/m/s² sensitivity, 4905 m/s² range, 0.914 m integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–55 to +160°C Operation |
|
3133A2 |
2 mV/g sensitivity, 2,500g range, 3–foot integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–67 to +320°F Operation
0.204 mV/m/s² sensitivity, 24525 m/s² range, 0.914 m integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–55 to +160°C Operation |
|
3133A3 |
5 mV/g sensitivity, 1000g range, 3–foot integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–67 to +320°F Operation
0.5 mV/m/s² sensitivity, 9810 m/s² range, 0.914 m integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–55 to +160°C Operation |
|
3133A4 |
0.7 mV/g sensitivity, 5,000g range, 3–foot integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–67 to +320°F Operation
0.07 mV/m/s² sensitivity, 49050 m/s² range, 0.914 m integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–55 to +160°C Operation |
|
3133A5 |
0.2 mV/g sensitivity, 20,000g range, 3–foot integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–67 to +320°F Operation
0.020 mV/m/s² sensitivity, 196200 m/s² range, 0.914 m integral cable to 4 pin 1/4–28 jack, adhesive mount, 0.8 grams,–55 to +160°C Operation |
|
3133B3 |
5 mV/g sensitivity, 1,000g range, ground isolated, 3–foot integral cable, adhesive mount, 1.84 grams,–60 to +250°F Operation
0.51 mV/m/s² sensitivity, 9810 m/s² range, ground isolated, 0.914 m integral cable, adhesive mount, 1.84 grams,–51 to +121°C Operation |
|
3133B7 |
5 mV/g sensitivity, 1000g range, ground isolated, 3–foot integral cable, adhesive mount, 1.84 grams,–67 to +320°F Operation
0.5 mV/m/s² sensitivity, 9810 m/s² range, ground isolated, 0.91m integral cable, adhesive mount, 1.84 grams,–55 to +160°C Operation |
|
3133B8 |
10 mV/g sensitivity, 500g range, ground isolated, 3–foot integral cable, adhesive mount, 1.84 grams,–60 to +250°F Operation
1.02 mV/m/s² sensitivity, 4905 m/s² range, ground isolated, 0.91m integral cable, adhesive mount, 1.84 grams,–55 to +121°C Operation |
|
3133D1 |
10 mV/g sensitivity, 500g range, 3–foot integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity (.001 g/µe ),–67 to +320°F Operation
1.02 mV/m/s² sensitivity, 4905 m/s² range, 0.914 m integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity (.001 g/µe ),–55 to +160°C Operation |
|
3133D18T |
5 mV/g sensitivity, 1,000g range, 3–foot integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity,–67 to +320°F Operation, TEDS
0.5 mV/m/s² sensitivity, 9810 m/s² range, 0.914 m integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity (.01 g/µe),–55 to +160°C Operation, TEDS |
|
3133D19T |
10 mV/g sensitivity, 500g range, 3–foot integral cable, adhesive mount, hermetically sealed, 1.3 grams, low base strain sensitivity,–67 to +320°F Operation, TEDS
1.0 mV/m/s² sensitivity, 4905 m/s² range, 0.914 m integral cable, adhesive mount, hermetically sealed, 1.3 grams, low base strain sensitivity (.01 g/µe),–55 to +160°C Operation, TEDS |
|
3133D1T |
10 mV/g sensitivity, 500g range, 3–foot integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity (.001 g/µe),–67 to +320°F Operation,–40 to +185°F TEDS Operation
1.02 mV/m/s² sensitivity, 4905 m/s² range, 0.914 m integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity (.001 g/µe),–55 to +160°C Operation,–40 to +85°C TEDS Operation |
|
3133D4T |
0.7 mV/g sensitivity, 5,000g range, 3–foot integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity (.001 g/µe),–67 to +320°F Operation,–40 to +185°F TEDS Operation
0.07 mV/m/s² sensitivity, 49050 m/s² range, 0.914 m integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity (.001 g/µe),–55 to +160°C Operation,–40 to +85°C TEDS Operation |
|
3133D5 |
0.25 mV/g sensitivity, 20,000g range, 3–foot integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity (.001 g/µe),–67 to +320°F Operation
0.026 mV/m/s² sensitivity, 196200 m/s² range, 0.914 m integral cable, adhesive mount, hermetically sealed, 0.8 grams, low base strain sensitivity (.001 g/µe),–55 to +160°C Operation |
|
|