Series 3093|Triaxial Sensor|Dytran

 

 
Triaxial Accelerometer

3093 series

Triaxial Accelerometer

The Dytran series 3093 is a case isolated triaxial IEPE accelerometer with a range of sensitivity from 1–100 mV/g sensitivity. The overall weight is 9.5–15 grams, and includes Transducer Electronic Data Sheet (TEDS) capabilities within
More Details...

Features:
  • Titanium
  • Hermetic
  • Case isolated
  • Low profile
  • Triaxial
  • TEDS options
  • IEPE
applications:
  • Modal and structural analysis
  • Noise, Vibration and Harshness (NVH)
  • Product response testing
  • Squeak & Rattle
  • General purpose triaxial vibration measurements
 
Model Variations
MODEL
SPECIFICATIONS
NEXT STEPS
3093B
100 mV/g sensitivity, 50g range, 4–pin Dytran designed 1/4–28 radial connector, adhesive mount, 9.5 grams,–60 to +225°F Operation
3093B1
100 mV/g sensitivity, 50g range, 4–pin Dytran designed 1/4–28 radial connector, 10–32 tapped hole, 13.5 grams,–60 to +225°F Operation
3093B1T
100 mV/g sensitivity, 50g range, 4–pin Dytran designed 1/4–28 radial connector, 10–32 tapped hole, 10 grams,–60 to +225°F Operation,–40 to +185°F TEDS Operation
3093D1
1 mV/g sensitivity, 500 g range, 4–pin industry standard side connector, 10–32 tapped hole, 14.0 grams,–60 to +250°F Operation
3093D2
5 mV/g sensitivity, 1000g range, 4–pin industry standard side connector, 10–32 tapped hole, 14.0 grams,–60 to +250°F Operation
3093D3
10 mV/g sensitivity, 500g range, 4–pin industry standard side connector, 10–32 tapped hole, 14.0 grams,–60 to +250°F Operation
3093D4
20 mV/g sensitivity, 250g range, 4–pin industry standard side connector, 10–32 tapped hole, 14.0 grams,–60 to +250°F Operation
3093D5
25 mV/g sensitivity, 200g range, 4–pin industry standard side connector, 10–32 tapped hole, 14.0 grams,–60 to +235°F Operation
3093D6
50 mV/g sensitivity, 100g range, 4–pin industry standard side connector, 10–32 tapped hole, 14.0 grams,–60 to +225°F Operation
3093D7
100 mV/g sensitivity, 50g range, 4–pin industry standard 1/4–28 radial connector, 10–32 tapped hole, 14 grams,–60 to +225°F Operation. Replacement for model 3093M17.
3093M18
10 mV/g sensitivity, 500g range, 4–pin industry standard 1/4–28 radial connector, 10–32 tapped hole, 15 grams,–60 to +250°F Operation,–40 to +185°F TEDS Operation
3093M23
5 mV/g sensitivity, 1000g range, 4–pin industry standard 1/4–28 radial connector, 10–32 stud mount, 15 grams,–60 to +250°F Operation
3093M27
 10 mV/g sensitivity, 500g range, 4–pin industry standard 1/4–28 radial connector, 10–32 tapped hole, 15 grams,–60 to +320°F Operation
3093M4
50 mV/g sensitivity, 100g range, 4–pin Dytran designed 1/4–28 radial connector, adhesive mount, 9.5 grams,–60 to +250°F Operation

Series 3093 Triaxial Accelerometer