MODEL
SPECIFICATIONS
NEXT STEPS
3056B10 |
10 mV/g sensitivity, 500g range, 10–32 axial connector, 1/4–28 mounting stud, mechanically and electrically filtered, 16 grams, isolated,–67 to +250°F Operation
1.02 mV/m/s² sensitivity, 4900 m/s² range, 10–32 axial connector, 1/4–28 mounting stud, mechanically and electrically filtered, 16 grams, isolated,–51 to +121°C Operation |
|
3056D1 |
10 mV/g sensitivity, 500g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–67 to +250°F Operation
1.02 mV/m/s² sensitivity, 4905 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–55 to +121°C Operation |
|
3056D11 |
50 mV/g sensitivity, 100g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–67 to +325°F Operation
5.1 mV/m/s² sensitivity, 981 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–55 to +163°C Operation |
|
3056D13 |
200 mV/g sensitivity, 25g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–67 to +325°F Operation
20.4 mV/m/s² sensitivity, 245 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–55 to +163°C Operation |
|
3056D14T |
500 mV/g sensitivity, 10g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–67 to +320°F Operation
51.0 mV/m/s² sensitivity, 98 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–55 to +160°C Operation |
|
3056D1T |
10 mV/g sensitivity, 500g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–60 to +250°F Operation,–40 to +185°F TEDS Operation
1.02 mV/m/s² sensitivity, 4905 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–51 to +121°C Operation,–40 to +85°C TEDS Operation |
|
3056D2 |
100 mV/g sensitivity, 50g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–67 to +250°F Operation
10.2 mV/m/s² sensitivity, 491 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–55 to +121°C Operation |
|
3056D2T |
100 mV/g sensitivity, 50g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–60 to +250°F Operation,–40 to +185°F TEDS Operation
10.2 mV/m/s² sensitivity, 491 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–51 to +121°C Operation,–40 to +85°C TEDS Operation |
|
3056D3 |
500 mV/g sensitivity, 10g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–67 to +225°F Operation
51.0 mV/m/s² sensitivity, 98 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–55 to +107°C Operation |
|
3056D4 |
20 mV/g sensitivity, 250g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–67 to +250°F Operation
2.04 mV/m/s² sensitivity, 2453 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–55 to +121°C Operation |
|
3056D4T |
20 mV/g sensitivity, 250g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–60 to +250°F Operation,–40 to +185°F TEDS Operation
2.04 mV/m/s² sensitivity, 2453 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–51 to +121°C Operation,–40 to +85°C TEDS Operation |
|
3056D5 |
50 mV/g sensitivity, 100g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–67 to +250°F Operation
5.1 mV/m/s² sensitivity, 981 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–55 to +121°C Operation |
|
3056D5T |
50 mV/g sensitivity, 100g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–60 to +250°F Operation,–40 to +185°F TEDS Operation
5.1 mV/m/s² sensitivity, 981 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–51 to +121°C Operation,–40 to +85°C TEDS Operation |
|
3056D6T |
200 mV/g sensitivity, 25g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–60 to +225°F Operation,–40 to +185°F TEDS Operation
20.4 mV/m/s² sensitivity, 245 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–51 to +107°C Operation,–40 to +85°C TEDS Operation |
|
3056D7T |
1 mV/g sensitivity, 5,000g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–60 to +250°F Operation,–40 to +185°F TEDS Operation
0.1 mV/m/s² sensitivity, 49050 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–51 to +121°C Operation,–40 to +85°C TEDS Operation |
|
3056D8T |
5 mV/g sensitivity, 1,000g range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–60 to +250°F Operation,–40 to +185°F TEDS Operation
0.51 mV/m/s² sensitivity, 9810 m/s² range, 10–32 axial connector, 10–32 tapped hole, 10 grams, isolated,–51 to +121°C Operation,–40 to +85°C TEDS Operation |
|
|